Ordering information
Product code: DDN-KP-003. Lead time may apply.
A PathoSeek research-use real-time PCR assay for K. pneumoniae DNA detection in environmental microbiology and research models.
Product code: DDN-KP-003. Lead time may apply.
50 reactions per kit. Contact Delphine Diagnostics for pricing, availability, and lead time.
Runs on standard real-time PCR platforms including ABI 7500, Bio-Rad CFX96, Roche LightCycler, and Rotor-Gene Q.
Product insert, Safety Data Sheet, and approved Instructions for Use can be provided with product documentation.
Multiplex, qualitative real-time PCR using TaqMan hydrolysis-probe chemistry.
All targets are detected simultaneously in a single reaction and reported as detected or not detected.
50 reactions per kit.
High sensitivity: detects fewer than 100 copies of target with greater than 95% priming efficiency.
Results in a few hours compared with several days for traditional culture.
Built-in positive, negative, and RNase P internal controls.
Runs on standard real-time PCR platforms including ABI 7500, Bio-Rad CFX96, Roche LightCycler, and Rotor-Gene Q.
Klebsiella pneumoniae is a significant Gram-negative bacterium frequently encountered in healthcare settings, known for its ability to cause a range of infections, from pneumonia and bloodstream infections to urinary tract infections.
Research on K. pneumoniae is critical due to the increasing prevalence of multi-drug-resistant strains. This kit enables detection of K. pneumoniae DNA within a sample for use in environmental microbiology, contamination studies, and experimental research models involving microbial pathogens.
Client feedback requested downloadable IFU content for PathoSeek. The sections below now include available shared product details from the feedback document; final reaction volumes, thermal cycling values, component quantities, storage temperatures, and troubleshooting rows should be completed from the approved IFU PDF.
Multiplex, qualitative real-time PCR using TaqMan hydrolysis-probe chemistry. Targets are detected simultaneously in a single reaction and reported as detected or not detected.
Runs on standard real-time PCR platforms including ABI 7500, Bio-Rad CFX96, Roche LightCycler, and Rotor-Gene Q. Final temperature and cycle-count values should come from the approved IFU.
50 reactions per kit with built-in positive, negative, and RNase P internal controls. Final vial quantities and storage temperatures should come from the approved IFU.
High sensitivity: detects fewer than 100 copies of target with greater than 95% priming efficiency. Final troubleshooting causes, corrective actions, and acceptance criteria should come from the approved IFU.
Contact Delphine Diagnostics for pricing, availability, lead time, documentation, and IFU updates.
This PathoSeek product is presented for research use only and is not described here as a diagnostic product for clinical decision-making.